Data Type Profile: DP_Quantity_1

Official URL: http://nphies.sa/fhir/ksa/nphies-fs/StructureDefinition/DP-Quantity-1 Version: 0.3.0
Draft as of 2025-06-23 Computable Name: DP_Quantity_1

Quantity datatype which only requires a value.

Usage:

  • Use this DataType Constraint: DP_Ratio

Formal Views of Profile Content

Description of Profiles, Differentials, Snapshots and how the different presentations work.

This structure is derived from Quantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
ksa-qty-1: May provide units as either as text or system and code
... value 1..1 DP_decimal Numerical value (with implicit precision)
... unit S 0..1 string Unit representation
Max Length:40
... system S 0..1 DP_uri System that defines coded unit form

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
ksa-qty-1: May provide units as either as text or system and code
... value Σ 1..1 DP_decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
... unit SΣ 0..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
Max Length:40
... code SΣ 0..1 DP_code Coded form of the unit
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()
NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
qty-3: If a code for the unit is present, the system SHALL also be present
ksa-qty-1: May provide units as either as text or system and code
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 1..1 DP_decimal Numerical value (with implicit precision)
... unit SΣ 0..1 string Unit representation
Max Length:40
... system SΣC 0..1 DP_uri System that defines coded unit form
... code SΣ 0..1 DP_code Coded form of the unit

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

Differential View

This structure is derived from Quantity

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
ksa-qty-1: May provide units as either as text or system and code
... value 1..1 DP_decimal Numerical value (with implicit precision)
... unit S 0..1 string Unit representation
Max Length:40
... system S 0..1 DP_uri System that defines coded unit form

doco Documentation for this format

Constraints

IdGradePath(s)DetailsRequirements
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))

Key Elements View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
ele-1: All FHIR elements must have a @value or children
qty-3: If a code for the unit is present, the system SHALL also be present
ksa-qty-1: May provide units as either as text or system and code
... value Σ 1..1 DP_decimal Numerical value (with implicit precision)
ele-1: All FHIR elements must have a @value or children
... comparator ?!Σ 0..1 code < | <= | >= | > - how to understand the value
Binding: QuantityComparator (required): How the Quantity should be understood and represented.


ele-1: All FHIR elements must have a @value or children
... unit SΣ 0..1 string Unit representation
ele-1: All FHIR elements must have a @value or children
Max Length:40
... code SΣ 0..1 DP_code Coded form of the unit
ele-1: All FHIR elements must have a @value or children

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

Snapshot View

NameFlagsCard.TypeDescription & Constraintsdoco
.. Quantity C 0..* Quantity A measured or measurable amount
qty-3: If a code for the unit is present, the system SHALL also be present
ksa-qty-1: May provide units as either as text or system and code
... id 0..1 string Unique id for inter-element referencing
... extension 0..* Extension Additional content defined by implementations
Slice: Unordered, Open by value:url
... value Σ 1..1 DP_decimal Numerical value (with implicit precision)
... unit SΣ 0..1 string Unit representation
Max Length:40
... system SΣC 0..1 DP_uri System that defines coded unit form
... code SΣ 0..1 DP_code Coded form of the unit

doco Documentation for this format

Terminology Bindings

PathConformanceValueSetURI
Quantity.comparatorrequiredQuantityComparator
http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
from the FHIR Standard

Constraints

IdGradePath(s)DetailsRequirements
ele-1error**ALL** elementsAll FHIR elements must have a @value or children
: hasValue() or (children().count() > id.count())
ext-1error**ALL** extensionsMust have either extensions or value[x], not both
: extension.exists() != value.exists()
ksa-qty-1errorQuantityMay provide units as either as text or system and code
: unit.exists().not() or (unit.exists() or (system.exists() and code.exists()))
qty-3errorQuantityIf a code for the unit is present, the system SHALL also be present
: code.empty() or system.exists()

 

Other representations of profile: CSV, Excel, Schematron